AC Cooling And Air Conditioning Systems Greenwood, South Carolina

At Home Comfort Systems, we install and service all brands of central air conditioning and cooling systems in Greenwood, SC. If you have an existing cooling system our trained staff can diagnosis your AC system and recommend terrific new high efficiency choices. We offer same day evaluation and prompt air conditioning installation services Greenwood, SC.

Let us help you decide how best to solve your air conditioning needs today.

Get Your Quote Today



Home Comfort Systems AC Cooling And Air Conditioning Systems Greenwood, South Carolina



Recent AC Cooling And Air Conditioning Systems Greenwood, South Carolina by Home Comfort Systems

American Standard HVAC ACONT4010AN21MA

GREENWOOD, SC
02-09-2017

ACONT4010AN21MA
Serviced Unit For Fall. Changed Filter, Checked And Cleaned.

GREENWOOD, SC
10-09-2015

ACONT4010AN21MA
Winter Service On HVAC Unit. Changed Filter And Cleaned.

GREENWOOD, SC
10-09-2015

ACONT4010AN21MA
Reset Limit On Water Heater

GREENWOOD, SC
10-08-2015

starstarstarstarstar
5 Star Rating
ACONT4010AN21MA
Preventative Maintenance On Several AC Units.

GREENWOOD, SC
10-08-2015

ACONT4010AN21MA
Relight Water Heater Pilot. Unit Is Working Properly.

GREENWOOD, SC
10-08-2015

ACONT4010AN21MA
Replaced Bin Sensor (eyes) On Ice Machine. Unit Is Working Properly.

GREENWOOD, SC
10-06-2015

ACONT4010AN21MA
Unit Was Froze Up. Repaired A Major Leak. Added Refrigerant And Installed A Tee At Condenser To Stop Leak, But There Are More Leaks In The Coils Thermostat Is Not Registering Correctly. May Need To Replace

GREENWOOD, SC
10-06-2015

ACONT4010AN21MA
Replaced The Inducer Fan Motor On Unit. Unit Is Working Properly At This Time.

GREENWOOD, SC
10-06-2015

ACONT4010AN21MA
AC Is Not Cooling. Had To Replace A Fuse In Unit. Unit Is Working Properly

GREENWOOD, SC
10-01-2015

ACONT4010AN21MA
Replaced Honeywell Pro 3000 Digital Thermostat, Old Thermostat Would Not Work And Clicked Continuously

GREENWOOD, SC
09-30-2015

ACONT4010AN21MA
Replaced Condenser Fan Motor In Unit. Unit Is Working Properly.

GREENWOOD, SC
09-30-2015

ACONT4010AN21MA
Kitchen Unit, Checked Drain And Refrigerant Charge

GREENWOOD, SC
09-29-2015

ACONT4010AN21MA
Cooler Is Not Cooling. Added Refrigerant To System, Unit Is Cooling Properly

GREENWOOD, SC
09-29-2015

ACONT4010AN21MA
HVAC Inspection.

GREENWOOD, SC
09-29-2015

ACONT4010AN21MA
Blowed Out Drain And Pumped Out Pan, Had To Add Refrigerant To System, No Leak Search. Unit Is Working Properly At This Time.

GREENWOOD, SC
09-28-2015

ACONT4010AN21MA
Blower Motor On AC Was Bad, Had To Replace And On The Split System, Found A Bad Capacitor Bad, Replaced It. Units Are Working Properly.

GREENWOOD, SC
09-24-2015

ACONT4010AN21MA
Found The Damper Closed. No Power On Motor To Open Damper. Checked At Fire Box Alarm. Has Power To Box, But Nothing Coming Out Of The Box. Problem In Fire Alarm System

GREENWOOD, SC
09-23-2015

ACONT4010AN21MA
Checked System For Proper Operation, Unit Is Working Properly At This Time.

GREENWOOD, SC
09-23-2015

ACONT4010AN21MA
Preventative Maintenance On AC Unit And Replaced The Thermostat

GREENWOOD, SC
09-23-2015

ACONT4010AN21MA
Increased Blower Speed And Flushed Drain Line. No Other Problems Found

GREENWOOD, SC
09-22-2015

ACONT4010AN21MA
Cut And Cleared Drain Line Assembly, Pumped Water From Auxillary Drain Pan

GREENWOOD, SC
09-22-2015

ACONT4010AN21MA
Checked System And Replaced Burnt Wires

GREENWOOD, SC
09-22-2015

ACONT4010AN21MA
A/C Broke Down And Needed To Be Recharged With Refrigerent

GREENWOOD, SC
09-11-2015